Thank you for choosing to fulfill your operational requirements for the Transformer Power NSN parts you require with Buy Ground Support Equipment. On this page, you can submit a quote request for Ametek Programmable Power Inc part number C-92204-2, a component that can also be found by inputting NSN 5950-00-160-5570 in our search engine. Alongside part number C-92204-2, we also have a wide range of other related items available, all of which can be traced back to a wealth of trusted manufacturers on our Approved Vendor List (AVL).
Buy Ground Support Equipment works with numerous government and defense agencies, so we use CAGE Codes like 25965 to uniquely identify items and their manufacturers in a standardized manner. We also utilize Federal Supply Classes (FSCs) to organize our inventory, ensuring customers can find Ametek Programmable Power Inc part number C-92204-2 by the FSC designation 5950 Coils and Transformers with ease. That being said, we encourage you to complete the RFQ form below for NSN 5950001605570 or any others that you are interested in, and we will provide you with a customized sourcing solution in 15 minutes or less. For one-on-one assistance, contact us via phone or email at any time; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-160-5570 Item PartTypeName: TRANSFORMER,POWER | 5950 | 001605570 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
92204-2 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 0.359 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.188 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.312 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 3.8 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY AND 50.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY AND 325.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 8.55 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 80.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY AND 550.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY AND 710.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
FEAT | SPECIAL FEATURES | TWO SECONDARY WINDINGS CENTER TAPPED AND GROUNDED TO CASE |
TTQY | TERMINAL TYPE AND QUANTITY | 13 WIRE LEAD |