Thank you for choosing to fulfill your operational requirements for the Starter Motor NSN parts you require with Buy Ground Support Equipment. On this page, you can submit a quote request for Carolina Power Systems Of Sumter part number TYPE 5AA2, a component that can also be found by inputting NSN 6110-01-503-3615 in our search engine. Alongside part number TYPE 5AA2, we also have a wide range of other related items available, all of which can be traced back to a wealth of trusted manufacturers on our Approved Vendor List (AVL).
Buy Ground Support Equipment works with numerous government and defense agencies, so we use CAGE Codes like 6Z538 to uniquely identify items and their manufacturers in a standardized manner. We also utilize Federal Supply Classes (FSCs) to organize our inventory, ensuring customers can find Carolina Power Systems Of Sumter part number TYPE 5AA2 by the FSC designation 6110 Electrical Control Equipment with ease. That being said, we encourage you to complete the RFQ form below for NSN 6110015033615 or any others that you are interested in, and we will provide you with a customized sourcing solution in 15 minutes or less. For one-on-one assistance, contact us via phone or email at any time; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6110-01-503-3615 Item PartTypeName: STARTER,MOTOR | 6110 | 015033615 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
TYPE 5AA2 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AGAV | End Item Identification | CONTROLLER,AC TYPE 5AA2 |
CBBL | Features Provided | CIRCUIT PROTECTION FUSE |
AGLD | Performance Type | MANUAL |
ACYN | Ac Voltage Rating | 440.0 VOLTS NOMINAL |
ANCN | Operating Voltage Characteristic | FULL |
AFLW | Actuation Method | MAGNETIC |
ANCY | Horsepower Rating | 25 |
FAAZ | Phase | THREE |
ANDX | Ambient Temp | 50.0 DEG CELSIUS |
FREQ | Frequency In Hertz | 60 |
ANDE | Actuator Voltage | 440.0 AC |
ANDW | Load Protection Type | OVERLOAD |
ACZB | Frequency Rating | 60.0 HERTZ NOMINAL |
ANPZ | Inclosure Feature | DRIPPROOF |
MRC | Decoded Requirement | Clear Text Reply |
ANQC | National Electrical Manufacturers Association Standards Design | NOT DESIGNED PER NEMA STD |
ANDG | Fuse Current Rating In Amps | 5.0 AND 10.0 |
CXCY | Part Name Assigned By Controlling Agency | (INAVY)CONTROLLER,MOTOR;(DRAWING)MOTOR CONTROLLER SS-50 FAN MOTOR ASSY(215-050-010) |
ABMK | Overall Width | 16.120 INCHES NOMINAL |
ABFE | Hazardous Locations/Environmental Protection | DRIPPROOF |
AGUE | Fuse Accommodation Quantity | 4 |
ABKW | Overall Height | 20.120 INCHES NOMINAL |
AQZF | Control Type | LOCAL |
AKPS | Duty Cycle | CONTINUOUS |