Thank you for choosing to fulfill your operational requirements for the Relay Electromagnetic NSN parts you require with Buy Ground Support Equipment. On this page, you can submit a quote request for Curtiss Wright Controls Inc part number 2510-1, a component that can also be found by inputting NSN 5945-01-374-5445 in our search engine. Alongside part number 2510-1, we also have a wide range of other related items available, all of which can be traced back to a wealth of trusted manufacturers on our Approved Vendor List (AVL).
Buy Ground Support Equipment works with numerous government and defense agencies, so we use CAGE Codes like 03972 to uniquely identify items and their manufacturers in a standardized manner. We also utilize Federal Supply Classes (FSCs) to organize our inventory, ensuring customers can find Curtiss Wright Controls Inc part number 2510-1 by the FSC designation 5945 Relays and Solenoids with ease. That being said, we encourage you to complete the RFQ form below for NSN 5945013745445 or any others that you are interested in, and we will provide you with a customized sourcing solution in 15 minutes or less. For one-on-one assistance, contact us via phone or email at any time; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-374-5445 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 013745445 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | G | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5D0036-1 | 5 | 2 | 1 |
MRC | Criteria | Characteristic |
---|---|---|
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC INDUCTIVE LOAD AND 3.0 AMPERES DC INDUCTIVE LOAD |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 SLOTTED HOLE SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINALS GOLD |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
ABHP | OVERALL LENGTH | 1.730 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 2.515 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.280 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AGAV | END ITEM IDENTIFICATION | C17A ACFT |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.05 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC LAMP LOAD AND 1.0 AMPERES DC LAMP LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC MOTOR LOAD AND 2.0 AMPERES DC MOTOR LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
PRMT | PRECIOUS MATERIAL | GOLD |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.