Thank you for choosing to fulfill your operational requirements for the Powersupply NSN parts you require with Buy Ground Support Equipment. On this page, you can submit a quote request for Electro Circuits Inc part number XMD415, a component that can also be found by inputting NSN 6130-01-036-3324 in our search engine. Alongside part number XMD415, we also have a wide range of other related items available, all of which can be traced back to a wealth of trusted manufacturers on our Approved Vendor List (AVL).
Buy Ground Support Equipment works with numerous government and defense agencies, so we use CAGE Codes like 07862 to uniquely identify items and their manufacturers in a standardized manner. We also utilize Federal Supply Classes (FSCs) to organize our inventory, ensuring customers can find Electro Circuits Inc part number XMD415 by the FSC designation 6130 Converters Electrical Non Rotating with ease. That being said, we encourage you to complete the RFQ form below for NSN 6130010363324 or any others that you are interested in, and we will provide you with a customized sourcing solution in 15 minutes or less. For one-on-one assistance, contact us via phone or email at any time; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-036-3324 Item PartTypeName: POWER SUPPLY | 6130 | 010363324 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
80098-1 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.425 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 0.800 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.510 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETICALLY SEALED |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APNX | INPUT VOLTAGE RATING | 22.0 DC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 30.0 DC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -15.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | -40.0/100.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | -100.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 100.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP SINGLE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 2 SINGLE OPERATING POWER RQMT |