Thank you for choosing to fulfill your operational requirements for the Circuit Breaker NSN parts you require with Buy Ground Support Equipment. On this page, you can submit a quote request for Sensata Technologies Inc part number PDA5, a component that can also be found by inputting NSN 5925-00-576-8179 in our search engine. Alongside part number PDA5, we also have a wide range of other related items available, all of which can be traced back to a wealth of trusted manufacturers on our Approved Vendor List (AVL).
Buy Ground Support Equipment works with numerous government and defense agencies, so we use CAGE Codes like 82647 to uniquely identify items and their manufacturers in a standardized manner. We also utilize Federal Supply Classes (FSCs) to organize our inventory, ensuring customers can find Sensata Technologies Inc part number PDA5 by the FSC designation 5925 Circuit Breakers with ease. That being said, we encourage you to complete the RFQ form below for NSN 5925005768179 or any others that you are interested in, and we will provide you with a customized sourcing solution in 15 minutes or less. For one-on-one assistance, contact us via phone or email at any time; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-576-8179 Item PartTypeName: CIRCUIT BREAKER | 5925 | 005768179 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
6010651-004 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABHP | OVERALL LENGTH | 2.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.250 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.906 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.781 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.312 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 30.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 575.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 130.0 SINGLE LOCATION |
CPRQ | RESET METHOD | AUTOMATIC |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 15.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS MAXIMUM SINGLE LOCATION |
CWJK | CASE MATERIAL | PLASTIC |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |