Thank you for choosing to fulfill your operational requirements for the Circuitbreaker NSN parts you require with Buy Ground Support Equipment. On this page, you can submit a quote request for Sensata Technologies Inc part number AP1-1-72-802, a component that can also be found by inputting NSN 5925-01-567-4938 in our search engine. Alongside part number AP1-1-72-802, we also have a wide range of other related items available, all of which can be traced back to a wealth of trusted manufacturers on our Approved Vendor List (AVL).
Buy Ground Support Equipment works with numerous government and defense agencies, so we use CAGE Codes like 81541 to uniquely identify items and their manufacturers in a standardized manner. We also utilize Federal Supply Classes (FSCs) to organize our inventory, ensuring customers can find Sensata Technologies Inc part number AP1-1-72-802 by the FSC designation 5925 Circuit Breakers with ease. That being said, we encourage you to complete the RFQ form below for NSN 5925015674938 or any others that you are interested in, and we will provide you with a customized sourcing solution in 15 minutes or less. For one-on-one assistance, contact us via phone or email at any time; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-567-4938 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015674938 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AP1-1-72-802 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CRTL | CRITICALITY CODE JUSTIFICATION | AGAV |
THSD | THREAD SERIES DESIGNATOR | UNEF |
ADAQ | BODY LENGTH | 1.562 INCHES MAXIMUM |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 800.0 SINGLE LOCATION |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK |
ABXD | BUSHING LENGTH | 0.380 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 1 |
AAQL | BODY STYLE | SINGLE POLE TYPE |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | CAGE: AP/UP MAGNETIC CIRCUIT PROTECTOR |
AGAV | III END ITEM IDENTIFICATION | AN/BQQ-10(V) UNIT 4190 TI06 PH3, HR OPERATOR CSL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.875 INCHES NOMINAL |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 8000.0 AMPERES DC SINGLE LOCATION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
ADAT | BODY WIDTH | 0.656 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
FREQ | FREQUENCY IN HERTZ | 50.0 OR 60.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC AND 50.0 DC SINGLE LOCATION |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.605 INCHES MAXIMUM |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 32000.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
ADTV | CASE MATERIAL | METAL |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.